blogit.fr: Blog multimédia 100% facile et gratuit

industrysourcing

Blog multimédia 100% facile et gratuit

 

BLOGIT

Blog dans la catégorie :
Autres

 

Statistiques

 




Signaler un contenu illicite

 

industrysourcing

Le 10/03/2017

 

M-1000 Analog Dual Sensor Controller

Le 16/01/2017

M-1000 Analog Dual Sensor Controller

· Analog Input
· Dual Sensor Control
· Temp. Compensation
· Communications Port RS485
· Thickness Measuring
· Sealed Front Panel (NEMA) 4
· Program Lock Access Code
· Enclosure 1/8 DIN
· Scaling of Display
· Power Supply 110 mA at 24 VDC

M-1000 Analog Dual Sensor Controller
 
 

Product Specification

M-1000 Control Meter

Features
· Analog Input
· Dual Sensor Control
· Temp. Compensation
· Communications Port RS485
· Thickness Measuring
· Sealed Front Panel (NEMA) 4
· Program Lock Access Code
· Enclosure 1/8 DIN
· Scaling of Display
· Power Supply 110 mA at 24 VDC

The M-1000 analog controller is a multipurpose dual sensor controller with a wide range of uses in the process control field. It was designed to work with any of Migatron’s analog output sensors as well as a temperature probe for temperature compensation. Its easy program modes allow instruction entry and review of previously programmed values. It accepts a standard 0-20 mA, 4-20 mA, 0-5V, 2-10V, 0-10V analog input. The microcontroller digitally scales the inputs with near and far scaling points, then this information is displayed on a 4 1/2 digit digital display. This attribute is also contained in an optional second channel input for added expandability. The controller can also supply 24 volts up to 110 mA to the sensors. The outputs consist of four solid state relays for use as outside limit monitors. These outputs can be programmed as either normally open or normally closed and can switch 2-130 VAC or VDC 100 mA DC or 50 mA AC continuous.

A RS485 serial communications port is also supplied. Communication can take place for baud rates of 300, 1200, 2400, 4800, and 9600. Each controller can be configured to transmit standard ASCII code up to a maximum distance of 10,000 feet. The M-1000 samples its inputs at a rate of 25 times per second, and includes auto zeroing. Its analog to digital converter is accurate to +- .05 mV and its converter is also rated as having a drift rating of 50 ppm per degree Celsius. The M-1000 is powered by 120 VAC, 8 watts and all of the inputs and outputs are tightly secured with reliable screw clamp cable connectors.

 

 

 

RPS-409A-IS2 Ultrasonic Sensor Certified Safe for Use In Explosive Environments

Le 11/01/2017

RPS-409A-IS2 Ultrasonic Sensor Certified Safe for Use In Explosive Environments

· Intrinsically Safe
· ANZEx, ATEX, IECEx, UL, cUL
· Input Voltage 16-30 VDC
· Reverse Polarity Protected
· Analog Voltage Output
· Short Circuit Protect
· Sync/Tx Input Line
· Various Sensing Ranges
· Wide Temperature Range
· Temperature Compensation

RPS-409A-IS2 Ultrasonic Sensor Certified Safe for Use In Explosive Environments
 
 

Product Specification

RPS-409A-IS2 Ultrasonic Sensor 
Certified Safe for Use In Explosive Environments

Features
· Intrinsically Safe
· ANZEx, ATEX, IECEx, UL, cUL
· Input Voltage 16-30 VDC
· Reverse Polarity Protected
· Analog Voltage Output
· Short Circuit Protect
· Sync/Tx Input Line
· Various Sensing Ranges
· Wide Temperature Range
· Temperature Compensation
· LED Indicator
· Self Contained Sensor
· PPS Enclosure
· No Training Required

About the RPS-409A-IS2 Sensor
Migatron now offers an ultrasonic sensor that has been certified for use in hazardous and explosive environments. The RPS-409A-IS2 is one of the first sensors ever to receive an ANZEx certificate for use in Australia and New Zealand. It has also been certified in Europe, the United States and Canada. It can be used in hazardous gas or dust environments classified as Zone 0, 1, 2, 20, 21 or 22 for ANZEx/ATEX/IECEx and Class I, II or III for UL/cUL when used with approved intrinsic safety barrier(s). The RPS-409A-IS2 is completely sealed with an IP67 rating.

Specifications

 

 

 

TGP Series Carbon Dioxide Detector/Transmitter - TGP Series

Le 20/12/2016

TGP Series Carbon Dioxide Detector/Transmitter - TGP Series

◆ Real-time detect CO2 level of indoor environment
◆ NDIR infrared CO2 sensor with Self-Calibration and up to 15 years lifetime
◆ Humidity and temperature detection optional
◆ Combined temperature and humidity sensor provide the highest accuracy in full range
◆ Wall mounting with the external sensor probe with the higher accuracy of measurements
◆ Providing one or three 0~10VDC or 4~20mA or 0~5VDC analog outputs
◆ Modbus RS485 communication interface makes usage and test more convenient
◆ Smart structure with the simple installation and wiring
◆ CE-Approval

TGP Series Carbon Dioxide Detector/Transmitter
 
 

TGP SERIES
Carbon Dioxide Detector/Transmitter

Features
◆ Real-time detect CO2 level of indoor environment
◆ NDIR infrared CO2 sensor with Self-Calibration and up to 15 years lifetime
◆ Humidity and temperature detection optional
◆ Combined temperature and humidity sensor provide the highest accuracy in full range
◆ Wall mounting with the external sensor probe with the higher accuracy of measurements
◆ Backlit LCD display option can display CO2 measurement and temperature+ RH measurements
◆ Providing one or three 0~10VDC or 4~20mA or 0~5VDC analog outputs
◆ Modbus RS485 communication interface makes usage and test more convenient
◆ Smart structure with the simple installation and wiring
◆ CE-Approval

Typical Applications
◆ HVAC systems
◆ In BAS to detect the CO2 level and the data transmittance
◆ Ventilation control system

Specifications

 

Temperature & Humidity Transmitter - F2000TSM-TH

Le 13/12/2016

Temperature & Humidity Transmitter - F2000TSM-TH

◆ Designed for transmit relative humidity measurement and temperature measurement.
◆ Provide up to 2x0~10VDC/4~20mA/0~5VDC outputs for humidity and temperature measurements
◆ Humidity output is automatically corrected over the full range of operating conditions
◆ Arbitrary point setup of temperature and humidity measurement modification
◆ Modbus RS485 communication is optional
◆ Wall mounting with the smart structure

F2000TSM-TH Temperature & Humidity Transmitter
 
 

Product Specification

F2000TSM-TH
Temperature & Humidity Transmitter
CE-Approval

Features
◆ Designed for transmit relative humidity measurement and temperature measurement.
◆ Provide up to 2x0~10VDC/4~20mA/0~5VDC outputs for humidity and temperature measurements
◆ Humidity output is automatically corrected over the full range of operating conditions
◆ Arbitrary point setup of temperature and humidity measurement modification
◆ Modbus RS485 communication is optional
◆ Wall mounting with the smart structure

Specifications

Models Information

Postfix 1: type of output signal
-V    0~10VDC (default)
-A    4~20mA
-V5  0~5VDC (not be changed )

Postfix 2: temperature scaling
T05:  0℃~50℃(32℉~122℉) default (without the postfix indicates the default)
T06:  0℃~60℃(32℉~140℉)
T26:  -20℃~60℃(-4℉~140℉)

For example: F2000TSM-TH-M100-V5-T06 indicates the transmitter with 1X 0~5VDC output, and the
temperature scaling is 0~60C.
F2000TSM-TH-M200-A indicates the transmitter with 1X 4~20mA output, and the temperature
scaling is the default (0~50℃).

 

Minibluff the card game

Hotels